Distributed Detection Grid

IMSI-SENSE

Every Corner Aware.

A grid of compact, passive RF detection nodes that blankets a facility with cellular awareness. Each PoE node detects device presence across 2G–5G and feeds a central engine, scaling to 128 nodes for building-wide geolocation without a single high-power unit.

Distributed Detection Grid

Detection as Infrastructure

Coverage comes from density, not from one powerful receiver in a rack. IMSI-SENSE spreads small passive nodes across ceilings and walls like access points, each reporting device presence and signal levels so the central engine can see — and locate — everything, everywhere, all the time.

Passive Detection Nodes

Each node passively detects 2G / 3G / 4G / 5G device activity across 700 MHz–6 GHz at −100 dBm sensitivity, reporting presence and RSSI without transmitting.

Grid Geolocation

With overlapping node coverage, the central engine triangulates devices to 3–8 m building-wide, improving as node density rises — no external antennas or alignment per node.

PoE-Simple Scale

Up to 128 nodes on one engine, each powered and networked over a single PoE cable at < 12 W, mounted AP-style in minutes with no RF cabling.

Feeds the Intelligence Stack

Node data flows straight into IMSI-TRACK PRO for identity capture and IMSI-TRACK ML for analytics, making the grid the sensory layer of the full platform.

The Result

  • Passive detection · 700 MHz–6 GHz · −100 dBm · 2G–5G
  • Grid geolocation 3–8 m building-wide, density-dependent
  • Up to 128 PoE nodes per engine · < 12 W · < 1 kg each
  • Direct feed into IMSI-TRACK PRO / ML
Technical Overview

Technical Specifications

Technical Equipment

Detection Node (SI-ISN-N1)

FunctionPassive detection (receive-only)
Frequency range700 MHz–6 GHz
Sensitivity−100 dBm (±3 dB)
Technologies2G / 3G / 4G / 5G
Measurement rate1–10 Hz

Ordering Information

Part numbers and configuration options

Part NumberDescriptionAvailability
SI-ISN-N1Passive detection node · indoor · PoEStandard
SI-ISN-ENGCentral detection engine · 1UStandard
SI-ISN-MNTUniversal ceiling / wall mountStandard
SI-ISN-SW-BASEGrid detection software licenseStandard
SI-ISN-N1-OUTPassive detection node · outdoor · IP65Optional
SI-ISN-SW-GEOEnhanced triangulation licenseOptional
Deployment

Implementation Process

1

Site Survey

  • Floor-plan capture
  • Coverage overlap plan
  • Target-band selection
  • Privacy policy
2

System Design

  • Node density and spacing for target precision
  • PoE switch sizing
  • Engine placement
  • PRO/ML integration
3

Installation

  • Ceiling/wall node mounting
  • Single-cable PoE runs
  • Engine commissioning
4

Calibration

  • Node RSSI calibration
  • Triangulation validation
  • Precision verification per zone
5

Training

  • Operator and administrator training
  • Presence and geolocation views
  • Maintenance
6

Go-Live

  • Grid activation
  • Live presence and geolocation
  • Feed to PRO/ML

Typical deployment timeline: 4-8 weeks depending on facility size and complexity

Frequently Asked Questions

Make Detection Part of the Building

Request a demonstration of building-wide passive detection by node density.

Related Product

IMSI-TRACK PRO

pair the sensory grid with identity capture and evidence-grade records.