Detect Once. Deny Forever.

SENTRA HYBRID

Detect Every Device. Deny It Forever.

SENTRA HYBRID unifies cellular intelligence and adaptive denial in one coordinated platform. An IMSI + ML detection layer identifies every device and hands it to a Jamming 4.0 denial layer, so a threat detected once is neutralized permanently — with C-UAS coordination and spillover held under the regulatory limit.

Detect Once. Deny Forever.

Intelligence and Denial, One Loop

Detection alone sees the problem; denial alone fights it blind. SENTRA HYBRID closes the loop: the intelligence layer identifies and geolocates every device, the ML denial layer neutralizes it with precision, and identity records make each action targeted, auditable and permanent.

Detection Layer (IMSI + ML)

Detects and identifies every device (IMSI/IMEI, 2G–5G) within 30 s, geolocates to 2–5 m, and applies ML behavioral analytics to prioritize threats and whitelist known devices in under 2 s.

Denial Layer (Jamming 4.0)

A predictive ML controller drives distributed inhibition nodes at up to 100 W per band, holding per-zone spillover ≤ the regulatory limit and re-converging in under 8 s as the environment changes.

Detect-Once / Deny-Forever Logic

Identity intelligence targets denial precisely and creates a permanent, evidence-linked record of each device, so a captured identity remains blocked across the estate rather than being re-fought each time.

C-UAS Coordination

A non-blocking REST API lets a Counter-UAS system momentarily free the 2.4 / 5 GHz bands it needs (/disable, /enable, /status; authenticated; < 500 ms; audited).

The Result

  • Detection < 30 s + geolocation 2–5 m + denial up to 100 W/band, one platform
  • Per-zone spillover ≤ regulatory limit · re-convergence < 8 s
  • Identity-targeted, evidence-linked, persistent denial
  • C-UAS-coordinated · on-premise · air-gapped capable
Technical Overview

Technical Specifications

Technical Equipment

Detection Layer

Technologies2G / 3G / 4G / 5G NSA + SA
Detection time< 30 s from power-on
Geolocation2–5 m (multi-sensor triangulation)
IdentifiersIMSI · IMEI · TMSI
ML analyticsBehavioral profiling · correlation · anomaly < 2 s

Ordering Information

Part numbers and configuration options

Part NumberDescriptionAvailability
SI-HYB-COREUnified detection + denial controllerStandard
SI-HYB-DETDetection unit (IMSI capture + geolocation)Standard
SI-HYB-ND88-module inhibition node (160–240 W)Standard
SI-HYB-SNPerimeter sensor (spillover + detection)Standard
SI-HYB-SW-MLML analytics + predictive denial licenseStandard
SI-HYB-HP44-module high-power inhibition cabinet (100 W/band, IP66)Optional
SI-HYB-UPSOnline double-conversion UPS · rack 2UOptional
SI-HYB-CUASC-UAS coordination interface licenseOptional
Deployment

Implementation Process

1

Site Survey

  • Facility layout
  • RF environment mapping
  • perimeter and zone definition
  • regulatory limits
  • C-UAS interface requirements
2

System Design

  • Detection sensor + inhibition node placement
  • per-zone spillover budgets
  • detect→deny policy
  • whitelist policy
  • C-UAS integration plan
3

Installation

  • Node and sensor mounting
  • unified controller commissioning
  • network and power
  • detection/denial cabling
4

Calibration

  • Per-zone ALC set-points
  • detection geolocation calibration
  • ML model training
  • spillover verification
  • C-UAS latency check
5

Training

  • Operator, administrator and compliance training
  • unified dashboard
  • detect→deny workflows
  • reporting
6

Go-Live

  • Full activation
  • detection→denial loop live
  • C-UAS coordination enabled
  • monitoring and support transition

Typical deployment timeline: 4-8 weeks depending on facility size and complexity

Frequently Asked Questions

Unify Intelligence and Denial in One Platform

Request a demonstration of the detect-once, deny-forever architecture.

Related Product

RF-JAM ZERO ML

RF-JAM ZERO ML for the denial layer and IMSI-TRACK ML for the intelligence layer — deployable independently or unified under SENTRA HYBRID.